.AixLib.DataBase.CHP.CHPDataSimple.CHP_Cleanergy_C9G

Information

Overview

Cleanergy mini-BHKW C9G (low caloric gas)

Concept

The electrical and thermal powers are in kW. The "fuel input" is in kW. The fuel consumption is in m³/h.

The calorific value of natural gas is assumed to be 11.5 kWh/m³ (10 - 12 kWh/m³).

Data Sheet (English, German)

Max. noise level dB(A)

49

Dimensions (L x W x H) cm

14.5 x 70 x 100

Floor area m2

0.70

Weight kg

470

Service interval hours

10,000

Fuels: natural gas (all qualities), mainly designed for low caloric gas (bio gas)

yes

Electrical output (modulating) kW

2 - 9

Thermal output kW

8 - 25

Power consumption (gas) kW

~36

Electrical efficiency

21 % (24% capacity), 24 % (80% capacity)

Thermal efficiency excluding optional condenser

58 % (24% capacity), 70 % (80% capacity)

Total efficiency excluding optional condenser

79 % (24% capacity), 94 % (80% capacity)

Flow temperature (constant) °C

60 – 65 (optimal: 50 °C)

Max. return temperature (variable) °C

50 (TRmin = 30 °C)



The CHP engine is not designed for continuous operation at more than 80% load (7.2 kW). Continuous use at higher load than 80% decreases the time between services.

For low methane applications, the C9G LowCal is capped to 120 bar engine pressure being equivalent to 7.2 kW.

Source:

Revisions


Generated at 2024-11-21T19:25:40Z by OpenModelicaOpenModelica 1.24.2 using GenerateDoc.mos