EC Power mini-BHKW XRGI 9 (Natural Gas)
The electrical and thermal powers are in kW. The fuel input is in kW. The fuel consumption is in m³/h.
The calorific value of natural gas is assumed to be 11.5 kWh/m³ (10 - 12 kWh/m³).
Max. noise level dB(A) |
49 |
Dimensions (L x W x H) cm |
92 x 64 x 96 |
Floor area m2 |
0.59 |
Weight kg</ p> |
440 |
Service interval hours |
10,000 |
Fuels: natural gas (all qualities), propane, butane |
yes |
Electrical output (modulating) kW |
4 - 9 |
Thermal output kW |
12 - 20 |
Power consumption (gas) kW |
31 |
Electrical efficiency |
29.5 % |
Thermal efficiency excluding optional condenser |
63.5 % |
Total efficiency excluding optional condenser |
93 % |
Flow temperature (constant) °C |
80 – 85 |
Max. return temperature (variable) °C |
5 – 75 |
Maximum exhaust gas temperature °C |
100 |
Emissions mg/Nm3 |
CO: < 50 NOX: < 100 |
Primary energy saving PES (EU Directive, verification in accordance with DIN 4709) |
22.4 % |
Emission |
< ½ TA Luft |
Primärenergieeinsparung PEE (EU-Richtlinie, Prüfung nach DIN 4709) |
22,4 % |
Primärenergiefaktor fp (EnEV 2009, EN15326) |
0,53 |
Source: