recordDIN_16893_SDR11_d50
PE-X Pipe, d_o=50mm, SDR11
Extends from DataBase.Pipes.PipeBaseDataDefinition (Base data definition of parameter values for pipes).
Information
Overview
Record for PE-X pipe.
Concept
The pipe dimensions are according to standard DIN 16893.
SDR is the diameter to wall thickness ratio.
d is the diameter in mm.
References
Record is used with AixLib.Fluid.FixedResistances.Pipe
Source:
- DIN 16983:2000-09
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| SI.Diameter | d_i (from PipeBaseDataDefinition) | Inner pipe diameter | |
| SI.Diameter | d_o (from PipeBaseDataDefinition) | Outer pipe diameter | |
| SI.Density | d (from PipeBaseDataDefinition) | Density of pipe material | |
| SI.ThermalConductivity | lambda (from PipeBaseDataDefinition) | Thermal conductivity of pipe material | |
| SI.SpecificHeatCapacity | c (from PipeBaseDataDefinition) | Heat capacity of pipe material |
Revisions
-
April 25, 2017 by Tobias Blacha:
Moved into AixLib -
January 29, 2014 by Ana Constantin:
Added to HVAC, formated and upgraded to current version of Dymola/Modelica -
March 13, 2012 by Tim Comanns (supervisor: Ana
Constantin):
Implemented.