recordIndoorSwimmingPoolBaseDataDefinition

Extends from Modelica.Icons.Record (Icon for records).

Information

This is the base definition of indoor swimming pool records used in AixLib.Fluid.Pools.IndoorSwimmingPool. It aggregates all parameters at one record to enhance usability, exchanging entire datasets and automatic generation of these datasets.

References

  • German Association of Engineers: Guideline VDI 2089-1, January 2010: Building Services in swimming baths - Indoor Pools
  • German Institute for Standardization DIN 19643-1, November 2012: Treatment of water of swimming pools and baths - Part 1 General Requirements
  • Chroistoph Saunus, 2005: Schwimmbäder Planung - Ausführung - Betrieb

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.TemperatureTPoolSet water temperature of swimming pool
Modelica.Units.SI.VolumeVPoolVolume of pool water
Modelica.Units.SI.AreaAPoolArea of water surface of swimming pool
Modelica.Units.SI.LengthdepthPoolAverage depth of swimming pool
Modelica.Units.SI.VolumeVStoUsable Volume of water storage, DIN 19643-1
Modelica.Units.SI.VolumeFlowRateV_flow_nominalCirculation volume flow rate
Modelica.Units.SI.VolumeFlowRateV_flow_parIn the case of partial load: circulation volume flow rate during non-opening hours, DIN 19643-1
Booleanuse_parLoafalsePartial load operation implemented for non opening hours?
Modelica.Units.SI.PressureDifferencedpHeaExcPoolPressure drop of heat exchanger, should be zero for an indeal heated pool
Booleanuse_ideHeaExctrueInclude an ideal heat exchanger into the circulation system
RealKHeatGain of controller for ideal heater
Modelica.Units.SI.TimetimeHeaTime constant of Integrator block for ideal heater
RealQMaxHeatUpper limit of output for ideal heater
RealQMinHeatLower limit of output for ideal heater
RealbetaInUseWater transfer coefficient during opening hours if pool is used, VDI 2089
Booleanuse_poolCovfalsePool covered during non opening hours
Booleanuse_watRecfalseRecycled water used for refilling pool water?
Realx_recPercentage of refilling water provided by recycled pool water, DIN 19643-1: <= 0,8
Modelica.Units.SI.MassFlowRatem_flow_outWaterexchange due to people in the pool, DIN 19643-1
Booleanuse_HRSfalseIs a heat recovery system physically integrated?
Modelica.Units.SI.EfficiencyetaHRSEffieciency of heat recovery system
Booleanuse_wavPoolfalseIs there a wave machine installed?
Modelica.Units.SI.LengthheiWavHeight of generated wave
Modelica.Units.SI.LengthwidWavWidth of generated wave/ width of wave machineoutlet
Modelica.Units.SI.TimetimeWavPul_startStart time of first wave cycle
Modelica.Units.SI.TimeperWavPulTime of cycling period
RealwidWavPulFraction of time of wave generation within cycling period
Modelica.Units.SI.AreaAWalIntArea of pool walls which is connected to inner rooms (inner pool walls)
Modelica.Units.SI.AreaAWalExtArea of pool walls which is connected to the ground (pool wall with earth contact)
Modelica.Units.SI.AreaAFloIntArea of pool floors which is connected to inner rooms (inner pool floor)
Modelica.Units.SI.AreaAFloExtArea of pool floors which is connected to teh ground (pool floor with earth contact)
Modelica.Units.SI.CoefficientOfHeatTransferhConWatHorMean value for the heat transfer coefficient of free convection on horizontal pool floors
Modelica.Units.SI.CoefficientOfHeatTransferhConWatVerMean value for the heat transfer coefficient of free convection on vertical pool walls