recordQPlusBFRG41285
Q.Plus BFR-G4.1 285
Extends from AixLib.DataBase.SolarElectric.PVBaseDataDefinition (Basic record of a PV module).
Information
References
Record for record used with AixLib.Fluid.Solar.Electric.PVsystem
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| General | |||
| Modelica.Units.SI.Efficiency | eta_0 (from PVBaseDataDefinition) | Efficiency under standard conditions. If not found in data sheet, use eta_0 = ((V_mp0*I_mp0)/(1000*A_cel*n_ser)) | |
| Real | n_ser (from PVBaseDataDefinition) | Number of cells connected in series on the PV panel | |
| Real | n_par (from PVBaseDataDefinition) | Number of parallel cell circuits on the PV panel | |
| Cell specific: Geometrical data | |||
| Modelica.Units.SI.Area | A_cel (from PVBaseDataDefinition) | Area of a single cell. If not found in data sheet, use A_cel = ((V_mp0*I_mp0)/(1000*eta_0))/n_ser | |
| Modelica.Units.SI.Area | A_pan (from PVBaseDataDefinition) | A_cel*n_ser*n_par | Area of one Panel, must not be confused with area of the whole module |
| Modelica.Units.SI.Area | A_mod (from PVBaseDataDefinition) | Area of one module (housing) | |
| Cell specific: Electrical characteristics | |||
| Modelica.Units.SI.Voltage | V_oc0 (from PVBaseDataDefinition) | Open circuit voltage under standard conditions | |
| Modelica.Units.SI.ElectricCurrent | I_sc0 (from PVBaseDataDefinition) | Short circuit current under standard conditions | |
| Modelica.Units.SI.Voltage | V_mp0 (from PVBaseDataDefinition) | MPP voltage under standard conditions | |
| Modelica.Units.SI.ElectricCurrent | I_mp0 (from PVBaseDataDefinition) | MPP current under standard conditions | |
| Modelica.Units.SI.Power | P_mp0 (from PVBaseDataDefinition) | MPP power of one PV module under standard conditions | |
| Real | TCoeff_Isc (from PVBaseDataDefinition) | Temperature coefficient for short circuit current, >0. If not found in data sheet, use TCoeff_Isc=alpha_Isc*I_sc0 and type in alpha_Isc manually | |
| Real | TCoeff_Voc (from PVBaseDataDefinition) | Temperature coefficient for open circuit voltage, <0. If not found in data sheet, use TCoeff_Voc=beta_Voc*V_oc0 and type in beta_Voc manually | |
| Modelica.Units.SI.LinearTemperatureCoefficient | alpha_Isc (from PVBaseDataDefinition) | TCoeff_Isc/I_sc0 | Normalized temperature coefficient for short circuit current, >0 |
| Modelica.Units.SI.LinearTemperatureCoefficient | beta_Voc (from PVBaseDataDefinition) | TCoeff_Voc/V_oc0 | Normalized temperature coefficient for open circuit voltage, <0 |
| Modelica.Units.SI.LinearTemperatureCoefficient | gamma_Pmp (from PVBaseDataDefinition) | Normalized temperature coefficient for power at MPP | |
| Modelica.Units.SI.Temperature | T_NOCT (from PVBaseDataDefinition) | Cell temperature under NOCT conditions | |
Revisions
-
May 6, 2021 by Laura Maier:
Adapted record which is also used in research project FUBIC suppored by the BMWi (promotional reference: 03ET1619)