recordSchuecoSPV170SME1

Schüco SPV 170 SME-1

Extends from AixLib.DataBase.SolarElectric.PVBaseDataDefinition (Basic record of a PV module).

Information

References

Record for record used with AixLib.Fluid.Solar.Electric.PVsystem

Parameters

TypeNameDefaultDescription
General
Modelica.Units.SI.Efficiencyeta_0 (from PVBaseDataDefinition)Efficiency under standard conditions. If not found in data sheet, use eta_0 = ((V_mp0*I_mp0)/(1000*A_cel*n_ser))
Realn_ser (from PVBaseDataDefinition)Number of cells connected in series on the PV panel
Realn_par (from PVBaseDataDefinition)Number of parallel cell circuits on the PV panel
Cell specific: Geometrical data
Modelica.Units.SI.AreaA_cel (from PVBaseDataDefinition)Area of a single cell. If not found in data sheet, use A_cel = ((V_mp0*I_mp0)/(1000*eta_0))/n_ser
Modelica.Units.SI.AreaA_pan (from PVBaseDataDefinition)A_cel*n_ser*n_parArea of one Panel, must not be confused with area of the whole module
Modelica.Units.SI.AreaA_mod (from PVBaseDataDefinition)Area of one module (housing)
Cell specific: Electrical characteristics
Modelica.Units.SI.VoltageV_oc0 (from PVBaseDataDefinition)Open circuit voltage under standard conditions
Modelica.Units.SI.ElectricCurrentI_sc0 (from PVBaseDataDefinition)Short circuit current under standard conditions
Modelica.Units.SI.VoltageV_mp0 (from PVBaseDataDefinition)MPP voltage under standard conditions
Modelica.Units.SI.ElectricCurrentI_mp0 (from PVBaseDataDefinition)MPP current under standard conditions
Modelica.Units.SI.PowerP_mp0 (from PVBaseDataDefinition)MPP power of one PV module under standard conditions
RealTCoeff_Isc (from PVBaseDataDefinition)Temperature coefficient for short circuit current, >0. If not found in data sheet, use TCoeff_Isc=alpha_Isc*I_sc0 and type in alpha_Isc manually
RealTCoeff_Voc (from PVBaseDataDefinition)Temperature coefficient for open circuit voltage, <0. If not found in data sheet, use TCoeff_Voc=beta_Voc*V_oc0 and type in beta_Voc manually
Modelica.Units.SI.LinearTemperatureCoefficientalpha_Isc (from PVBaseDataDefinition)TCoeff_Isc/I_sc0Normalized temperature coefficient for short circuit current, >0
Modelica.Units.SI.LinearTemperatureCoefficientbeta_Voc (from PVBaseDataDefinition)TCoeff_Voc/V_oc0Normalized temperature coefficient for open circuit voltage, <0
Modelica.Units.SI.LinearTemperatureCoefficientgamma_Pmp (from PVBaseDataDefinition)Normalized temperature coefficient for power at MPP
Modelica.Units.SI.TemperatureT_NOCT (from PVBaseDataDefinition)Cell temperature under NOCT conditions

Revisions

  • May 6, 2021 by Laura Maier:
    Adapted to new PV model