.AixLib.DataBase.Surfaces.RoughnessForHT.PolynomialCoefficients_ASHRAEHandbook

Information

Overview

Calculate the heat transfer coeficient alpha at outside surfaces depending on wind speed and surface type

Assumptions

Wind direction has no influence

Concept

alpha = D + E*V + R*V^2

References

Base data definition for record to be used in model AixLib.Utilities.HeatTransfer.HeatConv_outside

Source