recordEntrance

Swimming facility - Entrance hall

Extends from AixLib.DataBase.ThermalZones.ZoneBaseRecord (Base record definition for zone records).

Parameters

TypeNameDefaultDescription
Thermal Zone
BooleanwithAirCap (from ZoneBaseRecord)trueConsider capacity of indoor air
Modelica.Units.SI.VolumeVAir (from ZoneBaseRecord)Air volume of the zone
Modelica.Units.SI.AreaAZone (from ZoneBaseRecord)Net floor area of zone
Modelica.Units.SI.CoefficientOfHeatTransferhRad (from ZoneBaseRecord)Coefficient of heat transfer for linearized radiation exchange between walls
Modelica.Units.SI.Anglelat (from ZoneBaseRecord)Latitude of zone location
IntegernOrientations (from ZoneBaseRecord)Number of total facades with different combination of tilt and orientation
IntegerzoneInd (from ZoneBaseRecord)1Index of this zone in the multizone (starting at 1)
Modelica.Units.SI.ThermalConductanceheaLoadFacOut (from ZoneBaseRecord)Factor for heat load calculation (part 1) , needs to be multiplied with (indoor set temperature - nominal outside temperature)
Modelica.Units.SI.ThermalConductanceheaLoadFacGrd (from ZoneBaseRecord)Factor for heat load calculation, (part 2), needs to be multiplied with (indoor set temperature - nominal ground temperature)
Windows
Modelica.Units.SI.Area[nOrientations]AWin (from ZoneBaseRecord)Areas of windows by orientations
Modelica.Units.SI.Area[nOrientations]ATransparent (from ZoneBaseRecord)Areas of transparent (solar radiation transmittend) elements by orientations
Modelica.Units.SI.CoefficientOfHeatTransferhConWin (from ZoneBaseRecord)Convective coefficient of heat transfer of windows (indoor)
Modelica.Units.SI.ThermalResistanceRWin (from ZoneBaseRecord)Resistor for windows
Modelica.Units.SI.TransmissionCoefficientgWin (from ZoneBaseRecord)Total energy transmittance of windows
Modelica.Units.SI.CoefficientOfHeatTransferUWin (from ZoneBaseRecord)Thermal transmission coefficient of windows
RealratioWinConRad (from ZoneBaseRecord)Ratio for windows between convective and radiative heat emission
Modelica.Units.SI.CoefficientOfHeatTransferhConWinOut (from ZoneBaseRecord)Windows' convective coefficient of heat transfer (outdoor)
Real[nOrientations]wfWin (from ZoneBaseRecord)Weight factors of the windows
Exterior Walls
Modelica.Units.SI.Area[nOrientations]AExt (from ZoneBaseRecord)Areas of exterior walls by orientations
Modelica.Units.SI.CoefficientOfHeatTransferhConExt (from ZoneBaseRecord)Convective coefficient of heat transfer for exterior walls (indoor)
IntegernExt (from ZoneBaseRecord)Number of RC-elements of exterior walls
Modelica.Units.SI.ThermalResistance[nExt]RExt (from ZoneBaseRecord)Resistances of exterior walls, from inside to outside
Modelica.Units.SI.ThermalResistanceRExtRem (from ZoneBaseRecord)Resistance of remaining resistor RExtRem between capacity n and outside
Modelica.Units.SI.HeatCapacity[nExt]CExt (from ZoneBaseRecord)Heat capacities of exterior walls, from inside to outside
Modelica.Units.SI.EmissivityaExt (from ZoneBaseRecord)Coefficient of absorption of exterior walls (outdoor)
Modelica.Units.SI.Angle[nOrientations]tiltExtWalls (from ZoneBaseRecord)Tilts of exterior walls
Modelica.Units.SI.Angle[nOrientations]aziExtWalls (from ZoneBaseRecord)Azimuths of exterior walls
Modelica.Units.SI.CoefficientOfHeatTransferhConWallOut (from ZoneBaseRecord)Exterior walls convective coefficient of heat transfer (outdoor)
Modelica.Units.SI.CoefficientOfHeatTransferhRadWall (from ZoneBaseRecord)Coefficient of heat transfer for linearized radiation for exterior walls
Real[nOrientations]wfWall (from ZoneBaseRecord)Weight factors of the exterior walls
Interior Walls
Modelica.Units.SI.AreaAInt (from ZoneBaseRecord)Area of interior walls
Modelica.Units.SI.CoefficientOfHeatTransferhConInt (from ZoneBaseRecord)Convective coefficient of heat transfer of interior walls (indoor)
IntegernInt (from ZoneBaseRecord)Number of RC-elements of interior walls
Modelica.Units.SI.ThermalResistance[nInt]RInt (from ZoneBaseRecord)Resistances of interior wall, from port to center
Modelica.Units.SI.HeatCapacity[nInt]CInt (from ZoneBaseRecord)Heat capacities of interior walls, from port to center
Floor Plate
Modelica.Units.SI.AreaAFloor (from ZoneBaseRecord)Area of floor plate
Modelica.Units.SI.CoefficientOfHeatTransferhConFloor (from ZoneBaseRecord)Convective coefficient of heat transfer of floor plate (indoor)
IntegernFloor (from ZoneBaseRecord)Number of RC-elements of floor plate
Modelica.Units.SI.ThermalResistance[nFloor]RFloor (from ZoneBaseRecord)Resistances of floor plate, from inside to outside
Modelica.Units.SI.ThermalResistanceRFloorRem (from ZoneBaseRecord)Resistance of remaining resistor RFloorRem between capacity n and outside
Modelica.Units.SI.HeatCapacity[nFloor]CFloor (from ZoneBaseRecord)Heat capacities of floor plate, from inside to outside
Soil
Modelica.Units.SI.TemperatureTSoil (from ZoneBaseRecord)Temperature of soil (used for outside surface temperature of floors and thermal radiation)
AixLib.BoundaryConditions.GroundTemperature.DataSourceGroTemTSoiDatSou (from ZoneBaseRecord)AixLib.BoundaryConditions.GroundTemperature.DataSourceGroTem.Constantchoice for the data source of the outside surface temperature of floors
RealTSoiOffTim (from ZoneBaseRecord)6004800Time from simulation start to minimum soil temperature in s if sine model is chosen as TSoiDatSou
Modelica.Units.SI.TemperatureTSoiAmp (from ZoneBaseRecord)0Amplitude of TSoil if sine model is chosen as TSoiDatSou
StringTSoiFil (from ZoneBaseRecord)"NoName"File with TSoil table if file is chosen as TSoiDatSou
RealwfGro (from ZoneBaseRecord)Weight factor of the ground
Roof
Modelica.Units.SI.AreaARoof (from ZoneBaseRecord)Area of roof
Modelica.Units.SI.CoefficientOfHeatTransferhConRoof (from ZoneBaseRecord)Convective coefficient of heat transfer of roof (indoor)
IntegernRoof (from ZoneBaseRecord)Number of RC-elements of roof
Modelica.Units.SI.ThermalResistance[nRoof]RRoof (from ZoneBaseRecord)Resistances of roof, from inside to outside
Modelica.Units.SI.ThermalResistanceRRoofRem (from ZoneBaseRecord)Resistance of remaining resistor RRoofRem between capacity n and outside
Modelica.Units.SI.HeatCapacity[nRoof]CRoof (from ZoneBaseRecord)Heat capacities of roof, from inside to outside
IntegernOrientationsRoof (from ZoneBaseRecord)Number of orientations for roof
Modelica.Units.SI.Angle[nOrientationsRoof]tiltRoof (from ZoneBaseRecord)Tilts of roof
Modelica.Units.SI.Angle[nOrientationsRoof]aziRoof (from ZoneBaseRecord)Azimuths of roof
Real[nOrientationsRoof]wfRoof (from ZoneBaseRecord)Weight factors of the roof
Modelica.Units.SI.EmissivityaRoof (from ZoneBaseRecord)Coefficient of absorption of roof (outdoor)
Modelica.Units.SI.CoefficientOfHeatTransferhConRoofOut (from ZoneBaseRecord)Roof's convective coefficient of heat transfer (outdoor)
Modelica.Units.SI.CoefficientOfHeatTransferhRadRoof (from ZoneBaseRecord)Coefficient of heat transfer for linearized radiation for roof
Connection to other zones
IntegernIze (from ZoneBaseRecord)1Number of interzonal elements to consider
Modelica.Units.SI.Area[nIze]AIze (from ZoneBaseRecord){0.0}Area of interzonal elements
Modelica.Units.SI.CoefficientOfHeatTransfer[nIze]hConIze (from ZoneBaseRecord){0.0}Convective coefficient of heat transfer of interzonal elements (indoor)
IntegernIzeRC (from ZoneBaseRecord)1Number of RC-elements of interzonal elements
Modelica.Units.SI.ThermalResistance[nIze,nIzeRC]RIze (from ZoneBaseRecord){{0.00001}}Resistances of interzonal elements, from inside to outside
Modelica.Units.SI.ThermalResistance[nIze]RIzeRem (from ZoneBaseRecord){0.00001}Resistance of remaining resistor of interzonal elements between capacity nIzeRC and outside
.Modelica.Units.SI.HeatCapacity[nIze,nIzeRC]CIze (from ZoneBaseRecord){{0.00001}}Heat capacities of interzonal elements, from inside to outside
Integer[nIze]othZoneInd (from ZoneBaseRecord){1}Index of the zone in the multizone (starting at 1) to which each interzonal element is adjacent
Gains › Internal gains
RealspecificPeople (from ZoneBaseRecord)people per squaremeter
RealactivityDegree (from ZoneBaseRecord)acitivity degree of people in met
Modelica.Units.SI.HeatFlowRatefixedHeatFlowRatePersons (from ZoneBaseRecord)Area specific heatflowrate by persons in case of temperature independent calculation
RealratioConvectiveHeatPeople (from ZoneBaseRecord)Ratio of convective heat from overall heat output for people
RealinternalGainsMoistureNoPeople (from ZoneBaseRecord)internal moisture production of plants, etc. except from people in g/(h m²)
RealinternalGainsMachinesSpecific (from ZoneBaseRecord)Heat Flux of machines
RealratioConvectiveHeatMachines (from ZoneBaseRecord)Ratio of convective heat from overall heat output for machines
Modelica.Units.SI.HeatFluxlightingPowerSpecific (from ZoneBaseRecord)Heat flux of lighting
RealratioConvectiveHeatLighting (from ZoneBaseRecord)Ratio of convective heat from overall heat output for lights
Gains › External gains
Real[nOrientations]shadingFactor (from ZoneBaseRecord)Fc-Value: Factor representing how much of the actual solar irradiation goes through the sunblind and enters the window element, for the case, that the sunblind is activated. Defaults to 1, i.e. no shading is active. External sunblinds.
Real[nOrientations]maxIrr (from ZoneBaseRecord)Threshold value above which the sunblind (external) becomes active for the whole zone. Threshold regards to the incoming irradiation level with the window direction. This value does not account for heat flux due to the outside temperature.
Air exchange
BooleanuseConstantACHrate (from ZoneBaseRecord)falseChoose if a constant infiltration rate is used
RealbaseACH (from ZoneBaseRecord)Base ACH rate for ventilation controller
RealmaxUserACH (from ZoneBaseRecord)Additional ACH value for max. user activity
Real[2]maxOverheatingACH (from ZoneBaseRecord)Additional ACH value when overheating appears, transition range
Real[3]maxSummerACH (from ZoneBaseRecord)Additional ACH in summer, Tmin, Tmax
Real[3]winterReduction (from ZoneBaseRecord)Reduction factor of userACH for cold weather
Energy Supply › Heating
BooleanHeaterOn (from ZoneBaseRecord)trueUse heater component
RealhHeat (from ZoneBaseRecord)Upper limit controller output
ReallHeat (from ZoneBaseRecord)Lower limit controller output
RealKRHeat (from ZoneBaseRecord)Gain of the controller
Modelica.Units.SI.TimeTNHeat (from ZoneBaseRecord)Time constant of the controller
Modelica.Units.SI.TemperatureTThresholdHeater (from ZoneBaseRecord)Threshold temperature below ideal heater is used
Energy Supply › Cooling
BooleanCoolerOn (from ZoneBaseRecord)trueUse chiller component
RealhCool (from ZoneBaseRecord)Upper limit controller output
ReallCool (from ZoneBaseRecord)Lower limit controller output
RealKRCool (from ZoneBaseRecord)Gain of the controller
Modelica.Units.SI.TimeTNCool (from ZoneBaseRecord)Time constant of the controller
Modelica.Units.SI.TemperatureTThresholdCooler (from ZoneBaseRecord)Threshold temperature above ideal cooler is used
Energy Supply › Heating and Cooling
BooleanwithIdealThresholds (from ZoneBaseRecord)falseSets if the threshold temperatures for ideal heater and cooler should be used
Energy Supply › Air Handling Unit
BooleanwithAHU (from ZoneBaseRecord)trueZone is connected to central air handling unit
RealminAHU (from ZoneBaseRecord)Minimum specific air flow supplied by the AHU
RealmaxAHU (from ZoneBaseRecord)Maximum specific air flow supplied by the AHU
Initialization
Modelica.Units.SI.TemperatureT_start (from ZoneBaseRecord)Initial temperature