.AixLib.Electrical.Interfaces.Load

Information

This model represents a generic load that can be extended to represent either a DC or an AC load.

The model has a single generalized electric terminal of type AixLib.Electrical.Interfaces.Terminal that can be redeclared. The generalized load is modeled as an impedance whose value can change. The value of the impedance can change depending on the value of the parameter mode, which is of type AixLib.Electrical.Types.Load:

Mode Description Explanation
AixLib.Electrical.Types.Load.FixedZ_steady_state fixed Z steady state The load consumes exactly the power specified by the parameter P_nominal.
AixLib.Electrical.Types.Load.FixedZ_dynamic fixed Z dynamic The load consumes exactly the power specified by the parameter P_nominal at steady state. Depending on the type of load (e.g., inductive or capacitive) different dynamics are represented.
AixLib.Electrical.Types.Load.VariableZ_P_input variable Z P input The load consumes exactly the power specified by the input variable Pow.
AixLib.Electrical.Types.Load.VariableZ_y_input variable Z y input The load consumes exactly the a fraction of the nominal power P_nominal specified by the input variable y.

Conventions

It is assumed that the power P of the load is positive when produced (e.g., the load acts like a source) and negative when consumed (e.g., the source acts like a utilizer).

Linearized models

The model has a Boolean parameter linearized that by default is equal to false. When the power consumption of the load is imposed, this introduces a nonlinear equation between the voltage and the current of the load. This flag is used to select between a linearized version of the equations or the original nonlinear ones.
When the linearized version of the model is used, the parameter V_nominal has to be specified. The nominal voltage is needed to linearize the nonlinear equations.

Note: A linearized model will not consume the nominal power if the voltage at the terminal differs from the nominal voltage.

Contents

NameDescription
 PhaseSystemPhase system

Revisions