modelCellTemperatureMountingCloseToGround

Empirical model for determining the cell temperature of a PV module mounted with the module backsite close to the ground

Extends from AixLib.Electrical.PVSystem.BaseClasses.PartialCellTemperature (Partial model for determining the cell temperature of a PV moduleConnector for PV record data).

Information

Overview

Model for determining the cell temperature of a PV module mounted with the module backsite close to the ground, under operating conditions and under consideration of the wind velocity.


References

SANDIA REPORT SAND 2004-3535 Unlimited Release Printed December 2004 Photovoltaic Array Performance Model. (2005). by King, D. L. et al.

Parameters

TypeNameDefaultDescription
AixLib.DataBase.SolarElectric.PVBaseDataDefinitiondata (from PartialCellTemperature)
Modelica.Units.SI.Efficiencyeta_0 (from PartialCellTemperature)data.eta_0Efficiency under standard conditions
Modelica.Units.SI.TemperatureT_NOCT (from PartialCellTemperature)data.T_NOCTCell temperature under NOCT conditions
RealradNOCT (from PartialCellTemperature)800Irradiance under NOCT conditions

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealInputT_a (from PartialCellTemperature)Ambient temperature
Modelica.Blocks.Interfaces.RealInputwinVel (from PartialCellTemperature)Wind velocity
Modelica.Blocks.Interfaces.RealInputeta (from PartialCellTemperature)Efficiency of the PV module under operating conditions
Modelica.Blocks.Interfaces.RealInputradTil (from PartialCellTemperature)Total solar irradiance on the tilted surface
Modelica.Blocks.Interfaces.RealOutputT_c (from PartialCellTemperature)Cell temperature