modelCellTemperatureMountingContactToGround

Empirical model for determining the cell temperature of a PV module mounted with the module backsite in contact with the ground

Extends from AixLib.Electrical.PVSystem.BaseClasses.PartialCellTemperature (Partial model for determining the cell temperature of a PV moduleConnector for PV record data).

Information

Overview

Model for determining the cell temperature of a PV module mounted with the module backside in contact with the ground, under operating conditions and under consideration of the wind velocity. E.g. roof integrated PV modules.


References

SANDIA REPORT SAND 2004-3535 Unlimited Release Printed December 2004 Photovoltaic Array Performance Model. (2005). by King, D. L. et al.

Parameters

TypeNameDefaultDescription
AixLib.DataBase.SolarElectric.PVBaseDataDefinitiondata (from PartialCellTemperature)
Modelica.Units.SI.Efficiencyeta_0 (from PartialCellTemperature)data.eta_0Efficiency under standard conditions
Modelica.Units.SI.TemperatureT_NOCT (from PartialCellTemperature)data.T_NOCTCell temperature under NOCT conditions
RealradNOCT (from PartialCellTemperature)800Irradiance under NOCT conditions

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealInputT_a (from PartialCellTemperature)Ambient temperature
Modelica.Blocks.Interfaces.RealInputwinVel (from PartialCellTemperature)Wind velocity
Modelica.Blocks.Interfaces.RealInputeta (from PartialCellTemperature)Efficiency of the PV module under operating conditions
Modelica.Blocks.Interfaces.RealInputradTil (from PartialCellTemperature)Total solar irradiance on the tilted surface
Modelica.Blocks.Interfaces.RealOutputT_c (from PartialCellTemperature)Cell temperature