modelCellTemperatureOpenRack

Empirical model for determining the cell temperature of a PV module mounted on an open rack

Extends from AixLib.Electrical.PVSystem.BaseClasses.PartialCellTemperature (Partial model for determining the cell temperature of a PV moduleConnector for PV record data).

Information

Overview

Model for determining the cell temperature of a PV module mounted on an open rack under operating conditions and under consideration of the wind velocity.


References

Solar engineering of thermal processes. by Duffie, John A. ; Beckman, W. A.

Parameters

TypeNameDefaultDescription
AixLib.DataBase.SolarElectric.PVBaseDataDefinitiondata (from PartialCellTemperature)
Modelica.Units.SI.Efficiencyeta_0 (from PartialCellTemperature)data.eta_0Efficiency under standard conditions
Modelica.Units.SI.TemperatureT_NOCT (from PartialCellTemperature)data.T_NOCTCell temperature under NOCT conditions
RealradNOCT (from PartialCellTemperature)800Irradiance under NOCT conditions
Modelica.Units.SI.TemperatureT_a_0293.15Reference ambient temperature
Realcoeff_trans_abs0.9Module specific coefficient as a product of transmission and absorption. It is usually unknown and set to 0.9 in literature

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealInputT_a (from PartialCellTemperature)Ambient temperature
Modelica.Blocks.Interfaces.RealInputwinVel (from PartialCellTemperature)Wind velocity
Modelica.Blocks.Interfaces.RealInputeta (from PartialCellTemperature)Efficiency of the PV module under operating conditions
Modelica.Blocks.Interfaces.RealInputradTil (from PartialCellTemperature)Total solar irradiance on the tilted surface
Modelica.Blocks.Interfaces.RealOutputT_c (from PartialCellTemperature)Cell temperature