.AixLib.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.ThermalResponseFactors.Validation.FiniteLineSource_SteadyState

Test case for steady-state solution of the finite line source

Information

This example demonstrates the use of the function for the evaluation of the steady-state finite line source solution. The solution is evaluated at different distances between the emitting and receiving boreholes.

Revisions


Generated at 2025-03-09T19:25:01Z by OpenModelicaOpenModelica 1.24.5 using GenerateDoc.mos