.AixLib.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week

Information

This example validates the implementation of AixLib.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.GroundTemperatureResponse for the evaluation of the borehole wall temperature at a short time scale.

After a short delay, a sinusoidal heat flow rate is applied to borehole heat exchanger. The temperature at the borehole wall evaluated with AixLib.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.GroundTemperatureResponse is compared to the temperature obtained with AixLib.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Cylindrical

Revisions


Generated at 2024-12-22T19:25:51Z by OpenModelicaOpenModelica 1.24.3 using GenerateDoc.mos