.AixLib.Fluid.HeatPumps.ModularReversible.CarnotWithLosses

Information

Model of a reversible heat pump.

This model extends AixLib.Fluid.HeatPumps.ModularReversible.Modular and selects the constant Carnot effectiveness module for heat pumps ( AixLib.Fluid.HeatPumps.ModularReversible.RefrigerantCycle.ConstantCarnotEffectiveness) and chillers ( AixLib.Fluid.Chillers.ModularReversible.RefrigerantCycle.ConstantCarnotEffectiveness) to model a reversible heat pump. For the heating operation, the approach temperatures are fixed at nominal values to avoid nonlinear system of equations.

Furthermore, losses are enabled to model the heat pump with a more realistic behaviour:

For more information on the approach, see AixLib.Fluid.HeatPumps.ModularReversible.UsersGuide.

Revisions


Generated at 2024-10-29T19:25:38Z by OpenModelicaOpenModelica 1.24.0 using GenerateDoc.mos