.AixLib.Fluid.HeatPumps.ModularReversible.Data.TableData2D.EN14511.NIBE_F2050_10

NIBE F2050 10

Information

Data for air-to-water heat pump from NIBE. These tables are based on digitized data from manufacturer graphs. Temperature intervals are discretized with finer resolution in areas of high curvature to maintain accuracy. Electrical power PEle is calculated using the formula: PEle = Qmax / COP. Since manufacturers often provide COP and Qmax at different temperature points, PEle is calculated only at the temperature values common to both datasets to avoid extrapolation. As a result, the Qmax and PEle tables may differ in size.


NIBE F2050 Installateurhandbuch. Luft/Wasser-Wärmepumpe NIBE F2050.

Revisions


Generated at 2026-06-11T20:19:01Z by OpenModelicaOpenModelica 1.26.8 using GenerateDoc.mos