recordGenericHeatPump

Partial n-dimensional heat pump data

Extends from AixLib.Fluid.HeatPumps.ModularReversible.Data.TableDataSDF.Generic (Partial n-dimensional data of refrigerant machines).

Information

Record for n-dimensional heat pump performance data, enabling a selection for heating only data.

Parameters

TypeNameDefaultDescription
StringdevIde (from Generic)Name of the device
IntegernDim (from Generic)Number of table dimensions
Stringfilename (from Generic)File name of sdf table data
Real[nDim]facGai (from Generic)fill(1, nDim)Additional factor for inputs, e.g. scale relative compressor speed to match values in sdf tables
Booleanuse_TEvaOutForTab (from Generic)=true to use evaporator outlet temperature for table data, false for inlet
Booleanuse_TConOutForTab (from Generic)=true to use Useful outlet temperature for table data, false for inlet
Integer[nDim]outOrd (from Generic)1:nDimChange order of inputs
Electrical Power
StringdatasetPEle (from Generic)Dataset name for electrical power
StringdataUnitPEle (from Generic)Data unit for electrical power
String[nDim]scaleUnitsPEle (from Generic)Scale units for electrical power
Condenser heat flow
StringdatasetQCon_flowDataset name for useful heat flow rate
StringdataUnitQCon_flowData unit for useful heat flow rate
String[nDim]scaleUnitsQCon_flowScale units for useful heat flow rate