.AixLib.Fluid.HeatPumps.ModularReversible.RefrigerantCycle.Frosting.Functions.wetterAfjei1997

Information

Correction of the coefficient of performance due to icing/frosting according to Wetter, Afjei and Glass (1997).

For more information on the iceFac, see the documentation of AixLib.Fluid.HeatPumps.ModularReversible.RefrigerantCycle.BaseClasses.PartialRefrigerantCycle

References

Thomas Afjei, Michael Wetter and Andrew Glass.
TRNSYS type: Dual-stage compressor heat pump including frost and cycle losses. Model description and implementation in TRNSYS.
TRNSYS user meeting, November 1997, Stuttgart, Germany.
https://simulationresearch.lbl.gov/wetter/download/type204_hp.pdf

Interface

function wetterAfjei1997
  extends AixLib.Fluid.HeatPumps.ModularReversible.RefrigerantCycle.Frosting.Functions.partialIcingFactor;
end wetterAfjei1997;