This model validates the use of the mixing volume with adiabatic
cooling. Water in liquid form at room temperature is added to the
volume, which decreases its temperature. The instance
volSim uses a simplified implementation of the mass
balance that ignores the mass of the water added to the volume,
whereas the instance volExa uses the exact
formulation. The output of the instance relErr shows
that the relative error on the temperature difference between these
two options is less than 0.1%.
| Name | Description |
|---|---|
|
|
Medium model |