This model validates the power and efficiency computation using the Euler number and its correlation as implemented in AixLib.Fluid.Movers.BaseClasses.Euler. Its results of calculated efficiency and power are compared with those obtained using power curves.
Note that the power curve is still provided because it is required by AixLib.Fluid.Movers.BaseClasses.FlowMachineInterface. See AixLib.Fluid.Movers.Validation.ComparePowerHydraulic for a use case where the mover model is agnostic to the power curve and only the peak values are provided.