Overview
Model for the efficiency of a solar thermal collector. Inputs are
outdoor air temperature, fluid temperature and solar irradiation.
Based on these values and the collector properties from database,
this model calculates the heat flow to the fluid circuit. We assume
that the fluid temperature is equal to the collector temperature.
-
Febraury 7, 2018 by Peter Matthes:
Adds quatity information to RealInputs and RealOutputs.
-
February 1, 2018 by Philipp Mehrfeld:
eta must be between 0 and eta_zero optical efficiency
-
October 25, 2017 by Philipp Mehrfeld:
Limit eta to 0 and eta_zero.
Add correct units.
Avoid dividing by G=0.
-
December 15, 2016 by Moritz Lauster:
moved
-
November 11, 2013 by Marcus Fuchs:
implemented