.AixLib.Fluid.SolarCollectors.Data.Tubular.T_JiaxingDiyiC0130

Information

References

Ratings data taken from the Solar Rating and Certification Corporation website. SRCC# = 2012036A.

The ratings provided for dp_nominal were suspicious so 100 Pa is used instead.

Definition

record T_JiaxingDiyiC0130 = AixLib.Fluid.SolarCollectors.Data.GenericASHRAE93(final A = 4.650, final CTyp = AixLib.Fluid.SolarCollectors.Types.HeatCapacity.DryMass, final C = 0, final mDry = 95, final V = 1.7/1000, final dp_nominal = 100, final mperA_flow_nominal = 0.0142, final incAngDat = Modelica.Units.Conversions.from_deg({0, 10, 20, 30, 40, 50, 60, 70, 80, 90}), final incAngModDat = {1.0, 1.0222, 1.0897, 1.2034, 1.3596, 1.5272, 1.5428, 0.4206, 0.0, 0.0}, final y_intercept = 0.388, final slope = -1.453);

Generated at 2024-12-17T19:26:02Z by OpenModelicaOpenModelica 1.24.3 using GenerateDoc.mos