.AixLib.Media.Refrigerants.R410A.enthalpySatVap_T

Information

Function that calculates the specific enthalpy of saturated R410A vapor based on temperature.

References

Thermodynamic properties of DuPont Suva 410A: https://www.chemours.com/Refrigerants/en_US/assets/downloads/h64423_Suva410A_thermo_prop_si.pdf

Interface

function enthalpySatVap_T
  input Modelica.Units.SI.Temperature T "Temperature of refrigerant";
  output Modelica.Units.SI.SpecificEnthalpy h "Specific enthalpy of saturated liquid refrigerant";
end enthalpySatVap_T;

Revisions


Generated at 2024-12-25T19:25:50Z by OpenModelicaOpenModelica 1.24.3 using GenerateDoc.mos