recordVitocal200AWO201

Vitocal200AWO201

Extends from AixLib.Obsolete.Year2024.DataBase.HeatPump.HeatPumpBaseDataDefinition (Basic heat pump data).

Information

Data record for type AWO-M/AWO-M-E-AC 201.A04, obtained from the technical guide in the UK.

  • November 26, 2018  by Fabian Wüllhorst:
    First implementation (see issue #577)

Parameters

TypeNameDefaultDescription
Real[:,:]tableQdot_con (from HeatPumpBaseDataDefinition)Heating power table; T in degC; Q_flow in W
Real[:,:]tableP_ele (from HeatPumpBaseDataDefinition)Electrical power table; T in degC; Q_flow in W
Modelica.Units.SI.MassFlowRatemFlow_conNom (from HeatPumpBaseDataDefinition)Nominal mass flow rate in condenser
Modelica.Units.SI.MassFlowRatemFlow_evaNom (from HeatPumpBaseDataDefinition)Nominal mass flow rate in evaporator
Real[:,2]tableUppBou (from HeatPumpBaseDataDefinition)Points to define upper boundary for sink temperature