recordVitocal350BWH110
Vitocal 350 BWH 110
Extends from AixLib.Obsolete.Year2024.DataBase.HeatPump.HeatPumpBaseDataDefinition (Basic heat pump data).
Information
Data from manufacturer's data sheet (Viessmann). These exact curves are given in the data sheet for measurement procedure according to EN 255.
-
Oct 14, 2016 by Philipp Mehrfeld:
Transferred to AixLib.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real[:,:] | tableQdot_con (from HeatPumpBaseDataDefinition) | Heating power table; T in degC; Q_flow in W | |
| Real[:,:] | tableP_ele (from HeatPumpBaseDataDefinition) | Electrical power table; T in degC; Q_flow in W | |
| Modelica.Units.SI.MassFlowRate | mFlow_conNom (from HeatPumpBaseDataDefinition) | Nominal mass flow rate in condenser | |
| Modelica.Units.SI.MassFlowRate | mFlow_evaNom (from HeatPumpBaseDataDefinition) | Nominal mass flow rate in evaporator | |
| Real[:,2] | tableUppBou (from HeatPumpBaseDataDefinition) | Points to define upper boundary for sink temperature |