modelWindow_ASHRAE140

Window with transmission correction factor, modelling of window panes

Extends from AixLib.ThermalZones.HighOrder.Components.WindowsDoors.BaseClasses.PartialWindow (Partial model for windows).

Information

Overview

The WindowSimple model represents a window described by the thermal transmission coefficient and the coefficient of solar energy transmission( with correction factors).

Concept

Phenomena being simulated:

  • Solar energy transmission through the glass
  • Heat transmission through the whole window

References

Exemplary U-Values for windows from insulation standards

  • WschV 1984: specified "two panes" assumed 2,5 W/m2K
  • WschV 1995: 1,8 W/m2K
  • EnEV 2002: 1,7 W/m2K
  • EnEV 2009: 1,3 W/m2K

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.Areawindowarea (from PartialWindow)Total fenestration area
Modelica.Units.SI.TemperatureT0 (from PartialWindow)293.15Initial temperature
DataBase.WindowsDoors.Simple.OWBaseDataDefinition_SimpleWindowType (from PartialWindow)
AixLib.DataBase.WindowsDoors.ASHRAE140WithPanes.DefaultwinPaneRec
Connector usage › Inputs
Booleanuse_windSpeedPort (from PartialWindow)trueEnable wind speed input connector
Connector usage › Outputs
Booleanuse_solarRadWinTrans (from PartialWindow)trueEnable transmitted solar radiation output connector
Dynamics › Equations
Modelica.Fluid.Types.DynamicsenergyDynamicsModelica.Fluid.Types.Dynamics.SteadyStateType of energy balance: dynamic (3 initialization options) or steady state

Connectors

TypeNameDefaultDescription
Utilities.Interfaces.SolarRad_insolarRad_in (from PartialWindow)
Utilities.Interfaces.RadPortradPort (from PartialWindow)
Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_bport_inside (from PartialWindow)
Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_aport_outside (from PartialWindow)
Modelica.Blocks.Interfaces.RealInputWindSpeedPort (from PartialWindow)
Utilities.Interfaces.ShortRadSurfshortRadWin (from PartialWindow)

Components

TypeNameDefaultDescription
CorrSolGaincorrSolGain (from PartialWindow)Instance for correction of transimtted solar irradiance (shortwave radiation) through window
Modelica.Blocks.Math.GainA (from PartialWindow)
Modelica.Thermal.HeatTransfer.Components.ThermalConductorAirGap
Utilities.HeatTransfer.HeatConvOutsideheatConv_outside
Utilities.HeatTransfer.HeatConvInsideheatConv_inside
AixLib.ThermalZones.HighOrder.Components.Walls.BaseClasses.SimpleNLayerpane1
Utilities.HeatTransfer.HeatToRadtwoStar_RadEx
AixLib.ThermalZones.HighOrder.Components.Walls.BaseClasses.SimpleNLayerpane2
Modelica.Blocks.Sources.Constant[6]constFixShoRadParParameteres used for the short radiaton models. See connections to check which array corresponds to which parameter

Revisions

  • June, 18, 2020 by Fabian Wuellhorst:
    #918: Add short wave connector to pass window parameters.
  • April 23, 2020 by Philipp Mehrfeld:
    #752: Add records for window panes.
  • November 11, 2018  by Fabian Wüllhorst:
    Removed parameters phi and eps_out. This is for #651.
  • March 30, 2015  by Ana Constantin:
    Improved implementation of transmitted solar radiation
  • February 24, 2014  by Reza Tavakoli:
    First implementation