This example shows the application of AixLib.ThermalZones.ReducedOrder.RC.TwoElements in combination with AixLib.ThermalZones.ReducedOrder.EquivalentAirTemperature.VDI6007WithWindow and AixLib.ThermalZones.ReducedOrder.SolarGain.CorrectionGDoublePane. Solar radiation on tilted surface is calculated using models of AixLib. The thermal zone is a simple room defined in Guideline VDI 6007 Part 1 (VDI, 2012). All models, parameters and inputs except sunblinds, separate handling of heat transfer through windows and solar radiation are similar to the ones defined for the guideline's test room. For solar radiation, the example relies on the standard weather file in AixLib.
The idea of the example is to show a typical application of all sub-models and to use the example in unit tests. The results are reasonable, but not related to any real use case or measurement data.
VDI. German Association of Engineers Guideline VDI 6007-1 March 2012. Calculation of transient thermal response of rooms and buildings - modelling of rooms.
lat
from being a parameter to an input from weather bus.alphaWall
to hConWall
,
alphaWin
to hConWin
Modelica.Utilities.Files.loadResource
as this did not work for the regression tests.