modelCorrectionGTaueDoublePane
Extends from AixLib.ThermalZones.ReducedOrder.SolarGain.BaseClasses.PartialCorrectionGTaue (Partial model for correction of the solar gain factor and for the translucence).
Information
CorrectionGTaueDoublePane computes transmission correction factors for the g-factor and the translucence. Transmission properties of transparent elements are in general dependent on the solar incidence angle. To take this dependency into account, correction factors can multiplied with the solar radiation. These factors should not be mistaken as calculation of solar radiation on tilted surfaces, calculation of g-value or consideration of sunblinds, it is an additional step. The implemented calculations are defined in the German Guideline VDI 6007 Part 3 (VDI, 2015). The given model is only valid for double pane windows. The guideline describes also calculations for single pane and triple pane windows.
References
VDI. German Association of Engineers Guideline VDI 6007-3 June 2015. Calculation of transient thermal response of rooms and buildings - modelling of solar radiation.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Integer | n (from PartialCorrectionGTaue) | 1 | Number of windows |
| Modelica.Units.SI.CoefficientOfHeatTransfer | UWin (from PartialCorrectionGTaue) | Thermal transmission coefficient of whole window | |
| Modelica.Units.SI.Angle | xi (from PartialCorrectionGTaue) | 0 | Elevation angle |
| Modelica.Units.SI.Angle | til (from PartialCorrectionGTaue) | Surface tilt. til=90 degree for walls; til=0 for ceilings; til=180 for roof |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Blocks.Interfaces.RealOutput | corG_Dir (from PartialCorrectionGTaue) | Transmission coefficient correction factor for direct radiation | |
| Modelica.Blocks.Interfaces.RealOutput | corG_DifCle (from PartialCorrectionGTaue) | Transmission coefficient correction factor for diffuse radiation while clear sky | |
| Modelica.Blocks.Interfaces.RealOutput | corG_DifCov (from PartialCorrectionGTaue) | Transmission coefficient correction factor for diffuse radiation while covered sky | |
| Modelica.Blocks.Interfaces.RealOutput | corG_Gro (from PartialCorrectionGTaue) | Transmission coefficient correction factor for ground reflection radiation | |
| Modelica.Blocks.Interfaces.RealOutput | corTaue_Dir (from PartialCorrectionGTaue) | Correction value for translucence for direct irradiation | |
| Modelica.Blocks.Interfaces.RealOutput | corTaue_DifCle (from PartialCorrectionGTaue) | Correction value for translucence for diffuse irradiation during clear sky | |
| Modelica.Blocks.Interfaces.RealOutput | corTaue_DifCov (from PartialCorrectionGTaue) | Correction value for translucence for diffuse irradiation during covered sky | |
| Modelica.Blocks.Interfaces.RealOutput | corTaue_Gro (from PartialCorrectionGTaue) | Correction value for translucence for ground reflection radiation | |
| Modelica.Blocks.Interfaces.RealInput[n] | incAng (from PartialCorrectionGTaue) | Incidence angles of the sun beam on a tilted surface | |
| Modelica.Blocks.Interfaces.BooleanInput[n] | sunscreen (from PartialCorrectionGTaue) | True: sunscreen closed, false: sunscreen open |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.ReflectionCoefficient | xn2_Dir | Calculation factor to simplify equations | |
| Modelica.Units.SI.TransmissionCoefficient | tau_2Dir | Energetic degree of transmission for second pane | |
| Real | q21_Dir | Coefficient of heat transfer for exterior pane of double pane window | |
| Real | q22_Dir | Coefficient of heat transfer for interior pane of double pane window | |
| Real | qSek2_Dir | Overall coefficient of heat transfer for double pane window | |
| Modelica.Units.SI.ReflectionCoefficient | xn2_DifCle | Calculation factor to simplify equations | |
| Modelica.Units.SI.TransmissionCoefficient | tau_2DifCle | Energetic degree of transmission for second pane | |
| Real | q21_DifCle | Coefficient of heat transfer for exterior pane of double pane window | |
| Real | q22_DifCle | Coefficient of heat transfer for interior pane of double pane window | |
| Real | qSek2_DifCle | Overall coefficient of heat transfer for double pane window | |
| Modelica.Units.SI.ReflectionCoefficient | xn2_Gro | Calculation factor to simplify equations | |
| Modelica.Units.SI.TransmissionCoefficient | tau_2Gro | Energetic degree of transmission for second pane | |
| Real | q21_Gro | Coefficient of heat transfer for exterior pane of double pane window | |
| Real | q22_Gro | Coefficient of heat transfer for interior pane of double pane window | |
| Real | qSek2_Gro | Overall coefficient of heat transfer for double pane window |
Revisions
-
February 24, 2014 by Reza Tavakoli:
Implemented.
-
September 12, 2015 by Moritz Lauster:
Adapted to Annex 60 requirements.
-
May 25, 2016 by Stanley Risch:
Added the correction of the translucence factor according to VDI6007 Part 3