| Boolean | allowFlowReversal | false | = false to simplify equations, assuming, but not enforcing, no flow reversal |
| Modelica.Units.SI.MassFlowRate | m_flow_nominal | 0.2 | Nominal mass flow rate |
| Modelica.Units.SI.MassFlowRate | m_flow_small | 2E-05 | Small mass flow rate for regularization of zero flow |
| Modelica.Units.SI.MassFlowRate | _m_flow_start | 0 | Start value for m_flow, used to avoid a warning if not set in m_flow, and to avoid m_flow.start in parameter window |
| Modelica.Units.SI.PressureDifference | _dp_start | 0 | Start value for dp, used to avoid a warning if not set in dp, and to avoid dp.start in parameter window |
| Boolean | from_dp | false | = true, use m_flow = f(dp) else dp = f(m_flow) |
| Modelica.Units.SI.PressureDifference | dp_nominal | 10 | Pressure drop at nominal mass flow rate |
| Boolean | linearized | false | = true, use linear relation between m_flow and dp for any flow rate |
| Modelica.Units.SI.MassFlowRate | m_flow_turbulent | 0.06 | Turbulent flow if |m_flow| >= m_flow_turbulent |
| Modelica.Units.SI.MassFlowRate | m_flow_nominal_pos | 0.2 | Absolute value of nominal flow rate |
| Modelica.Units.SI.PressureDifference | dp_nominal_pos | 10 | Absolute value of nominal pressure difference |
| Real | deltaM | 0.3 | Fraction of nominal mass flow rate where transition to turbulent occurs |
| Real | k | 0.06324555320336758 | Flow coefficient, k=m_flow/sqrt(dp), with unit=(kg.m)^(1/2) |
| Boolean | computeFlowResistance | true | Flag to enable/disable computation of flow resistance |
| Real | coeff | 0 | Precomputed coefficient to avoid division by parameter |