recordInductionMachineData

Common parameters for induction machines

Extends from Modelica.Icons.Record (Icon for records).

Information

Basic parameters of induction machines are predefined with default values.

Parameters

TypeNameDefaultDescription
Integerm3Number of phases
Modelica.Units.SI.InertiaJr0.29Rotor's moment of inertia
Modelica.Units.SI.InertiaJsJrStator's moment of inertia
Integerp2Number of pole pairs (Integer)
Modelica.Units.SI.FrequencyfsNominal50Nominal frequency
RealeffectiveStatorTurns1Effective number of stator turns
Nominal resistances and inductances
Modelica.Units.SI.ResistanceRs0.03Stator resistance per phase at TRef
Modelica.Units.SI.TemperatureTsRef293.15Reference temperature of stator resistance
Modelica.Electrical.Machines.Thermal.LinearTemperatureCoefficient20alpha20s0Temperature coefficient of stator resistance at 20 degC
Modelica.Units.SI.InductanceLszeroLssigmaStator zero sequence inductance
Modelica.Units.SI.InductanceLssigma3*(1 - sqrt(1 - 0.0667))/(2*pi*fsNominal)Stator stray inductance per phase
Losses
Modelica.Electrical.Machines.Losses.FrictionParametersfrictionParametersFriction loss parameter record
Modelica.Electrical.Machines.Losses.CoreParametersstatorCoreParametersStator core loss parameter record; all parameters refer to stator side
Modelica.Electrical.Machines.Losses.StrayLoadParametersstrayLoadParametersStray load losses