blockBooleanPulseN
Generate pulse signal of type Boolean, extended with max number of pulses
Extends from Modelica.Blocks.Interfaces.partialBooleanSource (Partial source block (has 1 output Boolean signal and an appropriate default icon)).
Information
The Boolean output y is a pulse signal:
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | width | 50 | Width of pulse in % of period |
| Modelica.Units.SI.Time | period | Time for one period | |
| Modelica.Units.SI.Time | startTime | 0 | Time instant of first pulse |
| Integer | nperiod | -1 | Number of periods (< 0 means infinite number of periods) |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Blocks.Interfaces.BooleanOutput | y (from partialBooleanSource) | Connector of Boolean output signal |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Real | count |