modelInertia
Inertia of the volumetric flow
Extends from Interfaces.OnePort (Hydraulical OnePort), Icons.Inertance.
Information
Inertance I of the simple tube could be calculated as I=ro*l/A, where ro is fuid density, l is tube length and A is tube cross-section area.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Types.HydraulicInertance | I | Inertance | |
| Types.HydraulicResistance | R | 0 | optional additional resistance |
| Boolean | enabled | true | false for direct throughput, i.e. no inertance or resistance are applied |
| Initialization | |||
| Types.VolumeFlowRate | volumeFlow_start | 0.3 | Volumetric flow start value |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| HydraulicPort_a | q_in (from OnePort) | Volume inflow | |
| HydraulicPort_b | q_out (from OnePort) | Volume outflow |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Types.VolumeFlowRate | volumeFlowRate (from OnePort) | Volumetric flow | |
| Types.Pressure | dp (from OnePort) | Pressure gradient |
Revisions
2009-2010