modelMassInflow

One-directional inflow of heated mass with enthalpy (heat of solvation)

Extends from Interfaces.ConditionalMassFlow (Input of mass flow vs. parametric mass flow), Interfaces.ConditionalTemperature (Input of temperature vs. parametric temperature).

Parameters

TypeNameDefaultDescription
Types.MassFlowRateMassFlow (from ConditionalMassFlow)0Mass flow if useMassFlowInput=false
Types.TemperatureT (from ConditionalTemperature)0Temperature if useTemperatureInput=false
Types.SpecificEnergydH0Enthalpy of incoming substance (i.e. enthalpy of solvation)
Types.SpecificHeatCapacitySpecificHeat4186.8Of inflowing medium
External inputs/outputs
BooleanuseMassFlowInput (from ConditionalMassFlow)false=true, if mass flow input is used instead of parameter MassFlow
BooleanuseTemperatureInput (from ConditionalTemperature)false=true, if temperature input is used instead of parameter T

Connectors

TypeNameDefaultDescription
Types.RealIO.MassFlowRateInputmassFlow (from ConditionalMassFlow)q
Types.RealIO.TemperatureInputt (from ConditionalTemperature)temperature
Interfaces.HeatPort_bq_outflow circuit

Components

TypeNameDefaultDescription
Types.MassFlowRateq (from ConditionalMassFlow)Current mass flow
Types.Temperaturetemperature (from ConditionalTemperature)Current temperature

Revisions

2014

Marek Matejak, Charles University, Prague, Czech Republic