.BondLib.Electrical.Analog.Basic.CCV

Information

The linear current-controlled voltage source is built in bondgraphic technology using a flow detector and a modulated effort source. A-causal bonds must partially be used here, because the causality of the input and output ports depend on the embedding of the CCV element in its environment.


Parameters:

 transResistance:  Transresistance (default value = 1 Volt/Amp)


Equations:

v2 = transResistance*i1
v1 = 0


Generated at 2024-05-17T18:15:58Z by OpenModelicaOpenModelica 1.22.4 using GenerateDoc.mos