The linear current-controlled voltage source is built in bondgraphic technology using a flow detector and a modulated effort source. A-causal bonds must partially be used here, because the causality of the input and output ports depend on the embedding of the CCV element in its environment.
Parameters:
transResistance: Transresistance (default value = 1 Volt/Amp)
Equations:
v2 = transResistance*i1
v1 = 0
Generated at 2024-11-26T19:26:15Z