modelCWbulk
Condensation in the bulk
Extends from BondLib.Interfaces.TwoPort (Partial model invoking two bondgraphic connectors).
Information
This model computes the condensation in the bulk of the air. It uses the generic condensation model together with an internal modulation computing the conductance of condensation.An if statement is used to check whether the current humidity is above that of the dew point. If this is not the case, no condensation takes place.
Parameters: vai: Air volume of Biosphere (default value = 35000 m3) hai: Convection coefficient equation intercept (default value = 39.6 kJ/(h.m2.K)) pao: Atmospheric pressure (default value = 87.848 kPa)
References:
- American Society of Heating, Refrigerating and Air-Conditioning Engineers (1997), ASHRAE Handbook of Fundamentals.
- Air Psychrometrics
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | lambda | 2501 | Latent heat of vaporization |
| Modelica.SIunits.Volume | vai | 35000.0 | Air volume of Biosphere |
| Real | hai | 39.6 | Convection coefficient equation intercept |
| Real | pao | 87.848 | Atmospheric pressure |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| BondLib.Interfaces.BondCon | BondCon1 (from TwoPort) | Left bond graph connector | |
| BondLib.Interfaces.BondCon | BondCon2 (from TwoPort) | Right bond graph connector |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Real | e1 (from TwoPort) | Bondgraphic primary effort | |
| Real | f1 (from TwoPort) | Bondgraphic primary flow | |
| Real | e2 (from TwoPort) | Bondgraphic secondary effort | |
| Real | f2 (from TwoPort) | Bondgraphic secondary flow | |
| Real | ca | Specific heat capacity of moist air | |
| Real | G0 | Specific boundary layer conductance of condensation in the bulk | |
| Real | G | Boundary layer conductance of condensation | |
| Real | G2 | Bondgraphic conductance | |
| Real | svp | Saturation vapor pressure of air | |
| Real | hum | Humidity ratio of air at saturation | |
| mGSco | mGSco1 |