modelCWcov
Condensation at the dome
Extends from BondLib.Interfaces.TwoPort.
Information
This model computes the condensation at the dome. It uses the generic condensation model together with an internal modulation computing the conductance of condensation.An if statement is used to check whether the current humidity is above that of the dew point. If this is not the case, no condensation takes place.
Parameters: ac: Cover area of Biosphere (default value = 5667.0 m2) hai: Convection coefficient equation intercept (default value = 39.6 kJ/(h.m2.K)) pao: Atmospheric pressure (default value = 87.848 kPa)
References:
- American Society of Heating, Refrigerating and Air-Conditioning Engineers (1997), ASHRAE Handbook of Fundamentals.
- Air Psychrometrics
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | lambda | 2501 | Latent heat of vaporization |
| Modelica.SIunits.Area | ac | 5667.0 | Cover area of Biosphere |
| Real | hai | 39.6 | Convection coefficient equation intercept |
| Real | pao | 87.848 | Atmospheric pressure |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Real | ca | Specific heat capacity of moist air | |
| Real | G0 | Specific boundary layer conductance of condensation on cover | |
| Real | G | Boundary layer conductance of condensation | |
| Real | G2 | Bondgraphic conductance | |
| Real | svp | Saturation vapor pressure of cover | |
| Real | hum | Humidity ratio of cover at saturation | |
| mGSco | mGSco1 |