.BondLib.Semiconductors.Utilities.mC2

Information

This is an alternative model to the mC modulated capacitance model of the bond graph library. This model is physically dubious. Modelers are advised to always use the mC model, never the mC2 model. However, since this is the model that is being used in the Ebers-Moll description of bipolar transistors, it is being reproduced here. However, it is hidden under utilities to discourage modelers from using it.


Potential variables:

 e:  Bondgraphic effort variable

 f:  Bondgraphic flow variable, normalized positive for flows into the model

 C:  Capacitance (modulated input signal)


Equations:

f = C*der(e)


Generated at 2024-04-28T18:16:21Z by OpenModelicaOpenModelica 1.22.3 using GenerateDoc.mos