Units between Modelica and EnergyPlus are automatically converted, if they are specified. The conversion is according to the table at Buildings.Obsolete.ThermalZones.EnergyPlus_9_6_0.Types.Units.
To see what units are used, set printUnits=true
(the default) in the instance
Buildings.Obsolete.ThermalZones.EnergyPlus_9_6_0.Building. This
will cause the used units to be reported in the Modelica log
file.
The thermal zone model automatically converts the units.
To do unit conversion for values sent by
Buildings.Obsolete.ThermalZones.EnergyPlus_9_6_0.Actuator and
by
Buildings.Obsolete.ThermalZones.EnergyPlus_9_6_0.Schedule, set
the parameter unit to the unit of the variable
obtained at the input connector u. The value will then
be converted before it is sent to EnergyPlus. The units that are
used in the input u of this block are reported to the
Modelica log file.
To do unit conversion for values read by
Buildings.Obsolete.ThermalZones.EnergyPlus_9_6_0.OutputVariable,
Modelica will use the units reported by EnergyPlus. The units that
are used in the output y of this block are reported to
the Modelica log file.