.Buildings.Obsolete.ThermalZones.EnergyPlus_9_6_0.Validation.RunPeriod.StartDayOfYear

Validation model for the start day of the week

Information

This validation case simulates two instances of Buildings.Obsolete.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariable, a model that outputs the electricity consumption that is specified via an EnergyPlus schedule. This schedule set the electricity consumption to zero for the whole day on Saturday and Sunday, but not on other days. In the instance sun, the start day of the year is left as the default, which is Sunday, and in the instance mon, it is set to Monday. Plotting the electricity consumption verifies that the setting is properly applied in EnergyPlus.

Revisions


Generated at 2025-04-03T18:24:42Z by OpenModelicaOpenModelica 1.24.5 using GenerateDoc.mos