.Buildings.ThermalZones.Detailed.FLEXLAB.Data.Constructions.OpaqueConstructions.Roofs.CA_T24_2013Roof

Information

This is a model of a roof construction which is minimally compliant with CA Title 24-2013. It is used in test bed 90X2.

Note: This model is currently a work in progress. For more information see the documentation available at Buildings.ThermalZones.Detailed.FLEXLAB.UsersGuide.

Definition

record CA_T24_2013Roof = Buildings.HeatTransfer.Data.OpaqueConstructions.Generic(final material = {Buildings.HeatTransfer.Data.Solids.GypsumBoard(x = 0.016), Buildings.HeatTransfer.Data.Solids.InsulationBoard(x = 0.1016), Buildings.HeatTransfer.Data.Solids.Plywood(x = 0.0127)}, final nLay = 3);

Revisions


Generated at 2025-02-05T19:26:06Z by OpenModelicaOpenModelica 1.24.4 using GenerateDoc.mos