.Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice

Information

This package contains variable air volume flow models for a office building.

Note

The models Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.ASHRAE2006Winter and Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.Guideline36Winter appear to be quite similar to Buildings.Examples.VAVReheat.ASHRAE2006 and Buildings.Examples.VAVReheat.Guideline36, respectively, because they all have the same HVAC system, control sequences, and all have five thermal zones. However, the models in Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice are from the DOE Commercial Reference Building, Small Office, new construction, ASHRAE 90.1-2004, Version 1.3_5.0, whereas the models in Buildings.Examples.VAVReheat are from the DOE Commercial Building Benchmark, Medium Office, new construction, ASHRAE 90.1-2004, version 1.2_4.0. Therefore, the dimensions of the thermal zones in Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice are considerably smaller than in Buildings.Examples.VAVReheat. As the sizing is scaled with the volumes of the thermal zones, the model structure is the same, but the design capacities are different, as is the energy consumption.

Contents

NameDescription
ASHRAE2006SpringVariable air volume flow system with terminal reheat and five thermal zones using a control sequence published by ASHRAE in 2006
ASHRAE2006SummerVariable air volume flow system with terminal reheat and five thermal zones using a control sequence published by ASHRAE in 2006
ASHRAE2006WinterVariable air volume flow system with terminal reheat and five thermal zones using a control sequence published by ASHRAE in 2006
Guideline36SpringVariable air volume flow system with terminal reheat and five thermal zones controlled using an ASHRAE G36 controller
Guideline36SummerVariable air volume flow system with terminal reheat and five thermal zones controlled using an ASHRAE G36 controller
Guideline36WinterVariable air volume flow system with terminal reheat and five thermal zones controlled using an ASHRAE G36 controller
IdealHeatingCoolingSpringBuilding with constant fresh air and ideal heating/cooling that exactly meets set point
IdealHeatingCoolingSummerBuilding with constant fresh air and ideal heating/cooling that exactly meets set point
IdealHeatingCoolingWinterBuilding with constant fresh air and ideal heating/cooling that exactly meets set point
UnconditionedOpen loop model of one floor
BaseClassesPackage with base classes

Generated at 2024-05-16T18:15:58Z by OpenModelicaOpenModelica 1.22.4 using GenerateDoc.mos