.Buildings.ThermalZones.ReducedOrder.Examples.SimpleRoomOneElement

Information

This example shows the application of Buildings.ThermalZones.ReducedOrder.RC.OneElement in combination with Buildings.ThermalZones.ReducedOrder.EquivalentAirTemperature.VDI6007WithWindow and Buildings.ThermalZones.ReducedOrder.SolarGain.CorrectionGDoublePane. Solar radiation on tilted surface is calculated using models of Buildings. The thermal zone is a simple room defined in Guideline VDI 6007 Part 1 (VDI, 2012). All models, parameters and inputs except sunblinds, separate handling of heat transfer through windows, no wall element for internal walls and solar radiation are similar to the ones defined for the guideline's test room. For solar radiation, the example relies on the standard weather file in Buildings.

The idea of the example is to show a typical application of all sub-models and to use the example in unit tests. The results are reasonable, but not related to any real use case or measurement data.

References

VDI. German Association of Engineers Guideline VDI 6007-1 March 2012. Calculation of transient thermal response of rooms and buildings - modelling of rooms.