VDI 6007 Test Case 9 model
Test Case 9 of the VDI 6007 Part 1: Calculation of indoor air
temperature excited by a radiative and convective heat source for
room version S with two exterior walls. It is based on Test Case
8.
Boundary conditions
- daily profile for outdoor air temperature in hourly steps
- daily profile for solar radiation on the exterior wall
- daily profile for solar radiation through the windows in hourly
steps
- sunblind closes at >100 W/m2
- long-wave radiation exchange between exterior wall, windows and
ambient environment
This test validates reaction of indoor air temperature at mixed
internal gains and outdoor impacts including solar radiation and
long-wave radiation on exterior walls.
- July 11, 2019, by Katharina Brinkmann:
Renamed alphaWall to hConWall
- July 7, 2016, by Moritz Lauster:
Added automatic check against validation thresholds.
- January 11, 2016, by Moritz Lauster:
Implemented.
Generated at 2026-04-02T18:18:35Z by OpenModelicaOpenModelica 1.26.3 using