modelDoor

Partial door model for bi-directional flow

Extends from Buildings.Fluid.Interfaces.PartialFourPortInterface (Partial model with four ports and declaration of quantities that are used by many models).

Information

This is a partial model for the bi-directional air flow through a door.

Parameters

TypeNameDefaultDescription
Assumptions
BooleanallowFlowReversal1 (from PartialFourPort)true= false to simplify equations, assuming, but not enforcing, no flow reversal for medium 1
BooleanallowFlowReversal2 (from PartialFourPort)true= false to simplify equations, assuming, but not enforcing, no flow reversal for medium 2
Nominal condition
Modelica.Units.SI.MassFlowRatem1_flow_nominal (from PartialFourPortInterface)Nominal mass flow rate
Modelica.Units.SI.MassFlowRatem2_flow_nominal (from PartialFourPortInterface)Nominal mass flow rate
Advanced
Medium1.MassFlowRatem1_flow_small (from PartialFourPortInterface)1E-4*abs(m1_flow_nominal)Small mass flow rate for regularization of zero flow
Medium2.MassFlowRatem2_flow_small (from PartialFourPortInterface)1E-4*abs(m2_flow_nominal)Small mass flow rate for regularization of zero flow
Modelica.Units.SI.PressureDifferencedp_turbulent0.01Pressure difference where laminar and turbulent flow relation coincide
Advanced › Diagnostics
Booleanshow_T (from PartialFourPortInterface)false= true, if actual temperature at port is computed
Geometry
Modelica.Units.SI.LengthwOpe0.9Width of opening
Modelica.Units.SI.LengthhOpe2.1Height of opening

Connectors

TypeNameDefaultDescription
Modelica.Fluid.Interfaces.FluidPort_aport_a1 (from PartialFourPort)Fluid connector a1 (positive design flow direction is from port_a1 to port_b1)
Modelica.Fluid.Interfaces.FluidPort_bport_b1 (from PartialFourPort)Fluid connector b1 (positive design flow direction is from port_a1 to port_b1)
Modelica.Fluid.Interfaces.FluidPort_aport_a2 (from PartialFourPort)Fluid connector a2 (positive design flow direction is from port_a2 to port_b2)
Modelica.Fluid.Interfaces.FluidPort_bport_b2 (from PartialFourPort)Fluid connector b2 (positive design flow direction is from port_a2 to port_b2)

Components

TypeNameDefaultDescription
Medium1.MassFlowRatem1_flow (from PartialFourPortInterface)port_a1.m_flowMass flow rate from port_a1 to port_b1 (m1_flow > 0 is design flow direction)
Modelica.Units.SI.PressureDifferencedp1 (from PartialFourPortInterface)port_a1.p - port_b1.pPressure difference between port_a1 and port_b1
Medium2.MassFlowRatem2_flow (from PartialFourPortInterface)port_a2.m_flowMass flow rate from port_a2 to port_b2 (m2_flow > 0 is design flow direction)
Modelica.Units.SI.PressureDifferencedp2 (from PartialFourPortInterface)port_a2.p - port_b2.pPressure difference between port_a2 and port_b2
Medium1.ThermodynamicStatesta_a1 (from PartialFourPortInterface)if allowFlowReversal1 then Medium1.setState_phX(port_a1.p, noEvent(actualStream(port_a1.h_outflow)), noEvent(actualStream(port_a1.Xi_outflow))) else Medium1.setState_phX(port_a1.p, inStream(port_a1.h_outflow), inStream(port_a1.Xi_outflow))Medium properties in port_a1
Medium1.ThermodynamicStatesta_b1 (from PartialFourPortInterface)if allowFlowReversal1 then Medium1.setState_phX(port_b1.p, noEvent(actualStream(port_b1.h_outflow)), noEvent(actualStream(port_b1.Xi_outflow))) else Medium1.setState_phX(port_b1.p, port_b1.h_outflow, port_b1.Xi_outflow)Medium properties in port_b1
Medium2.ThermodynamicStatesta_a2 (from PartialFourPortInterface)if allowFlowReversal2 then Medium2.setState_phX(port_a2.p, noEvent(actualStream(port_a2.h_outflow)), noEvent(actualStream(port_a2.Xi_outflow))) else Medium2.setState_phX(port_a2.p, inStream(port_a2.h_outflow), inStream(port_a2.Xi_outflow))Medium properties in port_a2
Medium2.ThermodynamicStatesta_b2 (from PartialFourPortInterface)if allowFlowReversal2 then Medium2.setState_phX(port_b2.p, noEvent(actualStream(port_b2.h_outflow)), noEvent(actualStream(port_b2.Xi_outflow))) else Medium2.setState_phX(port_b2.p, port_b2.h_outflow, port_b2.Xi_outflow)Medium properties in port_b2
Modelica.Units.SI.VolumeFlowRateVAB_flowVolume flow rate from A to B if positive
Modelica.Units.SI.VolumeFlowRateVBA_flowVolume flow rate from B to A if positive
Modelica.Units.SI.VelocityvABAverage velocity from A to B
Modelica.Units.SI.VelocityvBAAverage velocity from B to A

Contents

NameDescription
MediumMedium in the component

Revisions

  • September 19, 2025, by Michael Wetter:
    Introduced protected parameter sqrt_dp_turbulent, which is needed to improve computing efficiency if flow exponent is 0.5.
    This is for IBPSA, #2043.
  • October 6, 2020, by Michael Wetter:
    First implementation for #1353.