| Buildings.Controls.OBC.ASHRAE.G36.ZoneGroups.GroupStatus | zonGroSta | | Calculate zone group status |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant[3] | warUpTim | | Warm-up time |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant[3] | cooDowTim | | Cooling down time |
| Buildings.Controls.OBC.CDL.Logical.Sources.Pulse[3] | winSta | | Window status |
| Buildings.Controls.OBC.CDL.Reals.Sources.Ramp | ramp2 | | Block that generates ramp signal |
| Buildings.Controls.OBC.CDL.Reals.Sin | sin2 | | Block that outputs the sine of the input |
| Buildings.Controls.OBC.CDL.Reals.MultiplyByParameter | gai | | Current zone temperature |
| Buildings.Controls.OBC.CDL.Reals.AddParameter | zonTem | | Current zone temperature |
| Buildings.Controls.OBC.CDL.Logical.Sources.Constant[3] | uOccOve | | Occupancy local override |
| Buildings.Controls.OBC.CDL.Logical.Sources.Pulse | zonOcc1 | | Zone 1 occupied status |
| Buildings.Controls.OBC.CDL.Logical.Sources.Pulse | zonOcc3 | | Zone 3 occupied status |
| Buildings.Controls.OBC.CDL.Logical.Not | not1 | | Logical not |
| Buildings.Controls.OBC.CDL.Logical.Not | not3 | | Logical not |
| Buildings.Controls.OBC.CDL.Logical.Timer | tim1 | | Time after input becomes true |
| Buildings.Controls.OBC.CDL.Logical.Timer | tim3 | | Time after input becomes true |
| Buildings.Controls.OBC.CDL.Reals.Subtract | addPar1 | | Time to occupied period |
| Buildings.Controls.OBC.CDL.Reals.Subtract | addPar3 | | Time to occupied period |
| Buildings.Controls.OBC.CDL.Logical.Sources.Pulse[3] | lowOccHea | | Lower than occupied heating setpoint |
| Buildings.Controls.OBC.CDL.Logical.Sources.Constant[3] | higOccCoo | | Higher than occupied cooling setpoint |
| Buildings.Controls.OBC.CDL.Logical.And[3] | and2 | | Lower than occupied heating setpoint when it is not occupied |
| Buildings.Controls.OBC.CDL.Logical.Sources.Pulse[3] | lowUnoHea1 | | Lower than unoccupied heating setpoint |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant[3] | heaSetOff | | Unoccupied heating setpoint |
| Buildings.Controls.OBC.CDL.Logical.Sources.Pulse[3] | endSetBac | | End setback |
| Buildings.Controls.OBC.CDL.Logical.Sources.Constant[3] | higUnoCoo | | HIgher than unoccupied cooling setpoint |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant[3] | cooSetOff | | Unoccupied cooling setpoint |
| Buildings.Controls.OBC.CDL.Logical.Sources.Constant[3] | endSetUp | | End setup mode |
| Buildings.Controls.OBC.CDL.Reals.Sources.Pulse | zonTem3 | | Zone 3 temperature |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | zonTem2 | | Zone 2 temperature |
| Buildings.Controls.OBC.CDL.Logical.Sources.Constant | zonOcc2 | | Zone 2 occupied status |
| Buildings.Controls.OBC.CDL.Logical.Not | not2 | | Logical not |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | tNexOcc2 | | Zone 2 next occupancy time |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | con | | Constant |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | con1 | | Constant |