recordReformEIRChiller_Carrier_19XR_1284kW_6_20COP_Vanes

ReformEIRChiller Carrier 19XR 1284kW/6.20COP/Vanes

A record of Buildings.Fluid.Chillers.Data.ElectricReformulatedEIR.Generic.

Information

Performance data for chiller model. This data corresponds to the following EnergyPlus model:
Chiller:Electric:ReformulatedEIR,
    ReformEIRChiller Carrier 19XR 1284kW/6.20COP/Vanes,  !- Name
    1283500,                 !- Reference Capacity {W}
    6.20,                    !- Reference COP {W/W}
    5.56,                    !- Reference Leaving Chilled Water Temperature {C}
    29.46,                   !- Reference Leaving Condenser Water Temperature {C}
    0.03684,                 !- Reference Chilled Water Flow Rate {m3/s}
    0.05337,                 !- Reference Condenser Water Flow Rate {m3/s}
    ReformEIRChiller Carrier 19XR 1284kW/6.20COP/Vanes CAPFT,  !- Cooling Capacity Function of Temperature Curve Name
    ReformEIRChiller Carrier 19XR 1284kW/6.20COP/Vanes EIRFT,  !- Electric Input to Cooling Output Ratio Function of Temperature Curve Name
    ReformEIRChiller Carrier 19XR 1284kW/6.20COP/Vanes EIRFPLR,  !- Electric Input to Cooling Output Ratio Function of Part Load Ratio Curve Name
    0.20,                    !- Minimum Part Load Ratio
    1.02,                    !- Maximum Part Load Ratio
    1.0,                     !- Optimum Part Load Ratio
    0.20,                    !- Minimum Unloading Ratio
    Chilled Water Side Inlet Node,  !- Chilled Water Inlet Node Name
    Chilled Water Side Outlet Node,  !- Chilled Water Outlet Node Name
    Condenser Side Inlet Node,  !- Condenser Inlet Node Name
    Condenser Side Outlet Node,  !- Condenser Outlet Node Name
    1.0,                     !- Compressor Motor Efficiency
    2.0,                     !- Leaving Chilled Water Lower Temperature Limit {C}
    ConstantFlow,            !- Chiller Flow Mode Type
    0.0;                     !- Design Heat Recovery Water Flow Rate {m3/s}

Attributes

NameValue
QEva_flow_nominal-1283500
COP_nominal6.20
PLRMin0.20
PLRMinUnl0.20
PLRMax1.02
mEva_flow_nominal1000*0.03684
mCon_flow_nominal1000*0.05337
TEvaLvg_nominal273.15 + 5.56
TConLvg_nominal273.15 + 29.46
TEvaLvgMin273.15 + 5.56
TEvaLvgMax273.15 + 8.89
TConLvgMin273.15 + 19.55
TConLvgMax273.15 + 30.85
capFunT{1.115795E+00, -2.963853E-02, -1.135671E-03, 4.184083E-03, -4.382921E-04, 2.096512E-03}
EIRFunT{7.586434E-01, -1.231609E-02, 1.784584E-03, -2.678401E-03, 6.302421E-04, -1.385469E-03}
EIRFunPLR{9.435414E-01, -6.553709E-02, 1.115089E-04, 1.530548E+00, -1.486930E+00, 6.031382E-02, 0.000000E+00, 7.320523E-02, 0.000000E+00, 0.000000E+00}
etaMotor1.0