recordReformEIRChiller_McQuay_PEH_1231kW_6_18COP_Vanes

ReformEIRChiller McQuay PEH 1231kW/6.18COP/Vanes

A record of Buildings.Fluid.Chillers.Data.ElectricReformulatedEIR.Generic.

Information

Performance data for chiller model. This data corresponds to the following EnergyPlus model:
Chiller:Electric:ReformulatedEIR,
    ReformEIRChiller McQuay PEH 1231kW/6.18COP/Vanes,  !- Name
    1230800,                 !- Reference Capacity {W}
    6.18,                    !- Reference COP {W/W}
    5.56,                    !- Reference Leaving Chilled Water Temperature {C}
    29.47,                   !- Reference Leaving Condenser Water Temperature {C}
    0.03533,                 !- Reference Chilled Water Flow Rate {m3/s}
    0.0511,                  !- Reference Condenser Water Flow Rate {m3/s}
    ReformEIRChiller McQuay PEH 1231kW/6.18COP/Vanes CAPFT,  !- Cooling Capacity Function of Temperature Curve Name
    ReformEIRChiller McQuay PEH 1231kW/6.18COP/Vanes EIRFT,  !- Electric Input to Cooling Output Ratio Function of Temperature Curve Name
    ReformEIRChiller McQuay PEH 1231kW/6.18COP/Vanes EIRFPLR,  !- Electric Input to Cooling Output Ratio Function of Part Load Ratio Curve Name
    0.10,                    !- Minimum Part Load Ratio
    1.03,                    !- Maximum Part Load Ratio
    1.0,                     !- Optimum Part Load Ratio
    0.10,                    !- Minimum Unloading Ratio
    Chilled Water Side Inlet Node,  !- Chilled Water Inlet Node Name
    Chilled Water Side Outlet Node,  !- Chilled Water Outlet Node Name
    Condenser Side Inlet Node,  !- Condenser Inlet Node Name
    Condenser Side Outlet Node,  !- Condenser Outlet Node Name
    1.0,                     !- Compressor Motor Efficiency
    2.0,                     !- Leaving Chilled Water Lower Temperature Limit {C}
    ConstantFlow,            !- Chiller Flow Mode Type
    0.0;                     !- Design Heat Recovery Water Flow Rate {m3/s}

Attributes

NameValue
QEva_flow_nominal-1230800
COP_nominal6.18
PLRMin0.10
PLRMinUnl0.10
PLRMax1.03
mEva_flow_nominal1000*0.03533
mCon_flow_nominal1000*0.0511
TEvaLvg_nominal273.15 + 5.56
TConLvg_nominal273.15 + 29.47
TEvaLvgMin273.15 + 5.56
TEvaLvgMax273.15 + 8.89
TConLvgMin273.15 + 20.98
TConLvgMax273.15 + 31.25
capFunT{1.253381E+00, 8.875124E-02, -8.323384E-03, -1.024474E-02, -6.751294E-04, 2.456063E-03}
EIRFunT{8.880010E-01, -9.202757E-03, -5.021594E-03, -9.074393E-03, 2.554841E-04, 2.313326E-03}
EIRFunPLR{1.651794E-01, -3.089335E-03, 2.301100E-04, 1.104907E+00, -8.157905E-01, -8.477359E-03, 0.000000E+00, 6.893449E-01, 0.000000E+00, 0.000000E+00}
etaMotor1.0