recordReformEIRChiller_McQuay_WSC_1519kW_7_10COP_Vanes

ReformEIRChiller McQuay WSC 1519kW/7.10COP/Vanes

A record of Buildings.Fluid.Chillers.Data.ElectricReformulatedEIR.Generic.

Information

Performance data for chiller model. This data corresponds to the following EnergyPlus model:
Chiller:Electric:ReformulatedEIR,
    ReformEIRChiller McQuay WSC 1519kW/7.10COP/Vanes,  !- Name
    1519200,                 !- Reference Capacity {W}
    7.10,                    !- Reference COP {W/W}
    8.89,                    !- Reference Leaving Chilled Water Temperature {C}
    31.76,                   !- Reference Leaving Condenser Water Temperature {C}
    0.03186,                 !- Reference Chilled Water Flow Rate {m3/s}
    0.08139,                 !- Reference Condenser Water Flow Rate {m3/s}
    ReformEIRChiller McQuay WSC 1519kW/7.10COP/Vanes CAPFT,  !- Cooling Capacity Function of Temperature Curve Name
    ReformEIRChiller McQuay WSC 1519kW/7.10COP/Vanes EIRFT,  !- Electric Input to Cooling Output Ratio Function of Temperature Curve Name
    ReformEIRChiller McQuay WSC 1519kW/7.10COP/Vanes EIRFPLR,  !- Electric Input to Cooling Output Ratio Function of Part Load Ratio Curve Name
    0.10,                    !- Minimum Part Load Ratio
    1.03,                    !- Maximum Part Load Ratio
    1.0,                     !- Optimum Part Load Ratio
    0.10,                    !- Minimum Unloading Ratio
    Chilled Water Side Inlet Node,  !- Chilled Water Inlet Node Name
    Chilled Water Side Outlet Node,  !- Chilled Water Outlet Node Name
    Condenser Side Inlet Node,  !- Condenser Inlet Node Name
    Condenser Side Outlet Node,  !- Condenser Outlet Node Name
    1.0,                     !- Compressor Motor Efficiency
    2.0,                     !- Leaving Chilled Water Lower Temperature Limit {C}
    ConstantFlow,            !- Chiller Flow Mode Type
    0.0;                     !- Design Heat Recovery Water Flow Rate {m3/s}

Attributes

NameValue
QEva_flow_nominal-1519200
COP_nominal7.10
PLRMin0.10
PLRMinUnl0.10
PLRMax1.03
mEva_flow_nominal1000*0.03186
mCon_flow_nominal1000*0.08139
TEvaLvg_nominal273.15 + 8.89
TConLvg_nominal273.15 + 31.76
TEvaLvgMin273.15 + 7.22
TEvaLvgMax273.15 + 12.78
TConLvgMin273.15 + 19.71
TConLvgMax273.15 + 33.53
capFunT{1.244930E+00, -3.988254E-02, -8.293893E-03, 3.053704E-02, -2.899547E-03, 9.784227E-03}
EIRFunT{1.087821E+00, -2.763242E-02, -3.692617E-03, -1.419848E-02, 6.903140E-05, 2.920296E-03}
EIRFunPLR{4.209093E-01, -1.860468E-02, 1.580518E-05, 8.654910E-01, -6.538795E-01, 1.786849E-02, 0.000000E+00, 3.759658E-01, 0.000000E+00, 0.000000E+00}
etaMotor1.0