recordReformEIRChiller_Trane_CVHF_1758kW_6_87COP_Vanes

ReformEIRChiller Trane CVHF 1758kW/6.87COP/Vanes

A record of Buildings.Fluid.Chillers.Data.ElectricReformulatedEIR.Generic.

Information

Performance data for chiller model. This data corresponds to the following EnergyPlus model:
Chiller:Electric:ReformulatedEIR,
    ReformEIRChiller Trane CVHF 1758kW/6.87COP/Vanes,  !- Name
    1758300,                 !- Reference Capacity {W}
    6.87,                    !- Reference COP {W/W}
    5.56,                    !- Reference Leaving Chilled Water Temperature {C}
    32.08,                   !- Reference Leaving Condenser Water Temperature {C}
    0.06309,                 !- Reference Chilled Water Flow Rate {m3/s}
    0.06309,                 !- Reference Condenser Water Flow Rate {m3/s}
    ReformEIRChiller Trane CVHF 1758kW/6.87COP/Vanes CAPFT,  !- Cooling Capacity Function of Temperature Curve Name
    ReformEIRChiller Trane CVHF 1758kW/6.87COP/Vanes EIRFT,  !- Electric Input to Cooling Output Ratio Function of Temperature Curve Name
    ReformEIRChiller Trane CVHF 1758kW/6.87COP/Vanes EIRFPLR,  !- Electric Input to Cooling Output Ratio Function of Part Load Ratio Curve Name
    0.20,                    !- Minimum Part Load Ratio
    1.03,                    !- Maximum Part Load Ratio
    1.0,                     !- Optimum Part Load Ratio
    0.20,                    !- Minimum Unloading Ratio
    Chilled Water Side Inlet Node,  !- Chilled Water Inlet Node Name
    Chilled Water Side Outlet Node,  !- Chilled Water Outlet Node Name
    Condenser Side Inlet Node,  !- Condenser Inlet Node Name
    Condenser Side Outlet Node,  !- Condenser Outlet Node Name
    1.0,                     !- Compressor Motor Efficiency
    2.0,                     !- Leaving Chilled Water Lower Temperature Limit {C}
    ConstantFlow,            !- Chiller Flow Mode Type
    0.0;                     !- Design Heat Recovery Water Flow Rate {m3/s}

Attributes

NameValue
QEva_flow_nominal-1758300
COP_nominal6.87
PLRMin0.20
PLRMinUnl0.20
PLRMax1.03
mEva_flow_nominal1000*0.06309
mCon_flow_nominal1000*0.06309
TEvaLvg_nominal273.15 + 5.56
TConLvg_nominal273.15 + 32.08
TEvaLvgMin273.15 + 5.56
TEvaLvgMax273.15 + 10.00
TConLvgMin273.15 + 20.44
TConLvgMax273.15 + 32.98
capFunT{7.950124E-01, 3.170632E-02, -5.547610E-04, 4.268492E-03, -1.289046E-04, 4.509069E-04}
EIRFunT{6.428117E-01, 1.299499E-02, 5.872739E-04, -5.532320E-03, 6.809308E-04, -1.480167E-03}
EIRFunPLR{5.682807E-01, -3.888781E-02, 6.619097E-06, 1.715735E+00, -1.791541E+00, 3.851853E-02, 0.000000E+00, 5.124705E-01, 0.000000E+00, 0.000000E+00}
etaMotor1.0