recordReformEIRChiller_Trane_CVHF_2043kW_9_08COP_Vanes

ReformEIRChiller Trane CVHF 2043kW/9.08COP/Vanes

A record of Buildings.Fluid.Chillers.Data.ElectricReformulatedEIR.Generic.

Information

Performance data for chiller model. This data corresponds to the following EnergyPlus model:
Chiller:Electric:ReformulatedEIR,
    ReformEIRChiller Trane CVHF 2043kW/9.08COP/Vanes,  !- Name
    2043100,                 !- Reference Capacity {W}
    9.08,                    !- Reference COP {W/W}
    4.44,                    !- Reference Leaving Chilled Water Temperature {C}
    23.11,                   !- Reference Leaving Condenser Water Temperature {C}
    0.09085,                 !- Reference Chilled Water Flow Rate {m3/s}
    0.11356,                 !- Reference Condenser Water Flow Rate {m3/s}
    ReformEIRChiller Trane CVHF 2043kW/9.08COP/Vanes CAPFT,  !- Cooling Capacity Function of Temperature Curve Name
    ReformEIRChiller Trane CVHF 2043kW/9.08COP/Vanes EIRFT,  !- Electric Input to Cooling Output Ratio Function of Temperature Curve Name
    ReformEIRChiller Trane CVHF 2043kW/9.08COP/Vanes EIRFPLR,  !- Electric Input to Cooling Output Ratio Function of Part Load Ratio Curve Name
    0.28,                    !- Minimum Part Load Ratio
    1.05,                    !- Maximum Part Load Ratio
    1.0,                     !- Optimum Part Load Ratio
    0.28,                    !- Minimum Unloading Ratio
    Chilled Water Side Inlet Node,  !- Chilled Water Inlet Node Name
    Chilled Water Side Outlet Node,  !- Chilled Water Outlet Node Name
    Condenser Side Inlet Node,  !- Condenser Inlet Node Name
    Condenser Side Outlet Node,  !- Condenser Outlet Node Name
    1.0,                     !- Compressor Motor Efficiency
    2.0,                     !- Leaving Chilled Water Lower Temperature Limit {C}
    ConstantFlow,            !- Chiller Flow Mode Type
    0.0;                     !- Design Heat Recovery Water Flow Rate {m3/s}

Attributes

NameValue
QEva_flow_nominal-2043100
COP_nominal9.08
PLRMin0.28
PLRMinUnl0.28
PLRMax1.05
mEva_flow_nominal1000*0.09085
mCon_flow_nominal1000*0.11356
TEvaLvg_nominal273.15 + 4.44
TConLvg_nominal273.15 + 23.11
TEvaLvgMin273.15 + 4.44
TEvaLvgMax273.15 + 8.89
TConLvgMin273.15 + 23.06
TConLvgMax273.15 + 34.90
capFunT{-2.215335E+00, -3.294601E-02, -5.300740E-03, 2.341598E-01, -4.558661E-03, 4.631243E-03}
EIRFunT{1.008753E+00, 3.282653E-02, 3.719189E-03, -2.508242E-02, 1.367676E-03, -3.739705E-03}
EIRFunPLR{3.696812E-01, 3.068332E-02, 1.965912E-05, -1.915197E+00, 3.980757E+00, -3.185207E-02, 0.000000E+00, -1.418416E+00, 0.000000E+00, 0.000000E+00}
etaMotor1.0